Power and cooling are coordinated with the rack layout from the first design stage.
Modular data centers
More power.Less footprint.
A complete data center in one 40ft module. Power, cooling, racks and control, engineered together and ready to deploy.
Discuss your project
40′ HIGH CUBE / DATA MODULECONCEPT VISUALIZATION- Power
- Cooling
- Security
- Control
01 / Platform
Everything you need.In one module.
A complete data center in a 40′ ISO container. Power, cooling, security and connectivity in one tested unit.
total module input
available for your servers
in each module
up to, per reference configuration

Technical parameters
- Container type
- ISO 40′ High Cube, 12,192 × 2,438 × 2,896 mm
- Installed power
- 100 kW, 400 V / 50 Hz
- IT capacity
- 75 kW, up to 12.5 kW per rack
- Capacity
- 6 × 42U racks
- Cooling
- 120 kW, N+1 redundancy, air / liquid (optional)
- Backup power
- UPS 2 × 100 kVA
- Fire protection
- Novec 1230 suppression, VESDA detection
- Security
- Electronic access control, 24/7 camera surveillance
- Connectivity
- 2 × 100 Gbps, optionally 400 Gbps, redundant fibre routes
- Ingress and operating range
- IP54, −20 °C to +45 °C
- Max. weight
- 28,000 kg
Installed power is the module’s total input (including cooling, UPS and other systems). IT capacity is the part available for your equipment.
02 / Inside the module
Complex technology.Simple by design.
Every system has a role. Together, they create the environment your data depends on.
Power, under control.
Integrated distribution, UPS and PLC controls connect the power infrastructure into one coordinated system.
DCIM monitoring and PLC controls provide visibility into the module’s operating conditions.
Access control, security monitoring and fire detection form an integrated protection concept.
How it works
Every container is a self-contained data center.
Inside are six 42U racks for servers, a distribution board, UPS, fire suppression and cable routes. The cooling units sit in a separate section behind a security cage. Two security doors with access control protect the entrance. A DCIM system connected to a monitoring centre watches the whole operation.

03 / Possibilities
Your ambition.Our infrastructure.
Rent capacity in our data centers, or have a container delivered turnkey.
Capacity rental
Place your servers in our container data centers. Rent part of a rack, a full rack or dedicated capacity. We provide power, cooling, connectivity and monitoring.
Turnkey delivery
We design, build, test and install a container data center at your site: an industrial plant, an energy source or an edge location. Everything from one supplier.
Higher density
A rack takes up to 12.5 kW and the container can be fitted with liquid cooling for higher density. Power and cooling are assessed against your hardware.
04 / Scale by design
Start with a module.Think in campuses.
Build capacity in phases. Add self-contained modules as your needs grow, with a clear view of the next step.

Containers can be combined into larger data centers to match the power you need. Connection to two independent fibre carriers over two separate routes, backup power and round-the-clock monitoring. Capacity can be rented by the unit (U) or by whole racks.
Illustrative scaling of the reference module. Final configuration depends on site conditions, power availability and connectivity.
05 / From vision to operation
A clear path.At every stage.
From the first engineering concept through manufacturing, integration and commissioning. One coordinated journey.
Inquiry
Your requirements: number of racks, power, location.
Design
Within 10 working days we prepare the technical solution and price.
Build and test
We build and test the container in our hall.
Transport and install
We deliver, position and connect it.
Operation and service
Monitoring, maintenance and support throughout operation.
The container is built and tested in a hall. On site it is simply positioned and connected.
All you need is a paved area, a power connection and fibre.
Start with one container and add more when you need them.
Fire suppression, early fire detection, access control and 24/7 cameras. Design prepared for NIS2 requirements.
06 / FAQ
Answers up front.
What do I need on site?
A paved area for the container (up to 28 t), a power connection of suitable capacity and access to fibre. We will assess the location with you.
How long does delivery take?
It depends on the configuration. We state the exact schedule in the quotation.
Can it handle AI and high-performance servers?
Yes. A rack takes up to 12.5 kW and the container can be fitted with liquid cooling for higher density.
Can the container be relocated later?
Yes. It is a standard ISO container that moves on an ordinary truck.
How is data security ensured?
Physically: two security doors, access control, cameras and fire protection. The design meets NIS2 requirements.
Can I rent just part of a rack?
Yes, we rent capacity by the unit (U) as well as by whole racks.
07 / The people behind the platform
Shared expertise.One direction.
CONTAINER DATA CENTERS brings together MCC, RSON and GTK. Engineering, construction and energy expertise for modular data infrastructure in the Czech Republic and Central Europe.